[UPDATED 2 October 2013] Gas hot water isn’t as sustainable as point-of-use instant electric systems under many circumstances, according to a new study out of RMIT University.
The study authors of the investigation into the environmental impacts of hot water systems said that current policies favouring gas and gas-solar hot water were “short-sighted”, and reflected a lack of a “whole-system” approach to measuring environmental impacts.
They said more flexibility was needed in Australian building policies to support innovation and future-proof technology relating to hot water systems.
The researchers from RMIT’s Centre for Design compared the life cycle impacts of gas centralised hot water with point-of-use instant electric systems in medium and high-density apartment buildings.

The buildings were:
- an existing high-density apartment complex, La Banque building, located in the Melbourne CBD at 380 Little Lonsdale Street, consisting of 257 apartments on 35 levels.
- a proposed medium-density apartment complex, the Brahe Place building, located in East Melbourne at 18 Brahe Place, consisting of eight apartments on three levels.
Alan Pears, senior lecturer in environment and planning at RMIT, said the results showed that electric systems could be the more sustainable option into the future in many cases.
“Our findings show there are significant opportunities today, and in coming years, for point-of-use electric systems to perform better than gas and solar-boosted gas, in greenhouse gas emissions and energy demand,” Mr Pears said.

“Context is the key to choosing environmentally friendlier hot water systems, and this research demonstrates why policymakers should consider a systems approach in regulation, rather than following product-specific rules of thumb.
“Because of their strong energy efficiency, point-of-use electric hot water systems could also be the choice to ensure future-proofing of developments, as future grid emission reductions combine with efficiency for strong environmental outcomes.”
Comparing the two systems over the life cycle in the 257-apartment building and the eight-apartment block, the study found:
- point-of-use electric was up to 3.1 times more energy efficient than gas in the medium-density block (up to 1.6 times compared with solar-boosted gas)
- point-of-use electric was up to 2.3 times more energy efficient than gas in the high-density building
“The apartment buildings had pumped ring main hot water systems, which have very large heat losses,” Mr Pears told The Fifth Estate. “Also, apartments typically have fewer people and lower hot water usage. So a precise electric water heating option near the point of use, such as the Microheat unit evaluated, can do quite a good job.”
As to why dedicated solar systems weren’t part of the study, Mr Pears said: “Individual solar hot water systems would not be particularly straightforward because of limited roof space and long distances from the roof, and capital costs would be very high.
“So use of solar would still require a ring main, with its associated large losses. It would be feasible to consider an unboosted central solar system with a ring main – preferably much better insulated than standard Australian practice – and the point of use electric boosters. That would involve significantly higher capital costs, though.”
Responding to possible issues associated with increased peak demand from electric systems, Mr Pears said: “With regard to the

peak demand issue, the cost of higher capacity wiring was included in the analysis. With regard to actual peak impact, it’s difficult to take a definitive position. Apartments typically have only one shower and fewer people. With a water-efficient shower head, the instantaneous electricity demand is not enormous, and the diversity of timing of usage reduces the impact of the overall building on the peak.
“There is certainly a broader issue in managing peaks, especially now that many people are installing induction cooktops with very high peak demand – although it is usually for short periods.”
Mr Pears said that the study did not claim electric hot water was the solution in all situations.
“However, where the distribution losses are high and hot water usage is low, such as in many apartment buildings, they can be very useful. That’s why the case studies analysed were apartment buildings.”
While the study found gas currently scored better on greenhouse gas emissions in coal-reliant Victoria, it said the electric system could perform better into the future as our energy mix changes.
The independent research, which assessed greenhouse gas emissions, water use, solid waste and cumulative energy demand – and included the use of dynamic thermal modelling software – was commissioned by Australian-owned MicroHeat Technologies, developers of an electric hot water system that does not use heat exchangers such as those tested in the study.
Read the full report: https://bit.ly/15wAUwE